Article - CS404064

Installation of information modeler failing during odata validation in Windchill PDMLink

Modified: 18-Sep-2024   


Applies To

  • FlexPLM 12.1.2.0
  • Windchill PDMLink 12.0 to 12.1

Description

  • Installation aborting during version validation of Odata
  • Error reported on PSI logs:
    •  validate.version: 
       Property "env.PATH" has not been set 
            [exec] Current OS is Windows Server 2019 
            [exec] Setting environment variable: Path=C:\Program Files\Amazon Corretto\jdk11.0.16_8\bin;C:\Program Files\ImageMagick-7.1.0-Q16-HDRI;C:\Windows\system32;C:\Windows;C:\Windows\System32\Wbem;C:\Windows\System32\WindowsPowerShell\v1.0;C:\Windows\System32\OpenSSH;C:\Program Files\gs\gs10.00.0\bin;C:\Program Files\Microsoft Network Monitor 3;C:\Program Files\postgresql-13.3-2-Client\pgsql\bin;F:\ThingWorxFoundation\tomcat\apache-tomcat-9.0.52\bin;F:\ThingWorxFoundation\tomcat\current\webapps\Thingworx\WEB-INF\extensions;F:\ThingWorxFoundation\tomcat\current\webapps\Thingworx\WEB-INF\lib;F:\ThingWorxFoundation\tomcat\current\webapps\Thingworx\WEB-INF\extensions\FlxCore64.dll;C:\Users\Boxineadmin\AppData\Local\Microsoft\WindowsApps 
            [exec] Setting environment variable: PATH=C:\Program Files\Amazon Corretto\jdk11.0.16_8\bin;F:\Staging_FlexPLM\MED-61383-CD-120_12-0-2-0\${env.PATH} 
            [exec] Executing 'F:\ptc\Windchill_12.0\Windchill\bin\windchill' with arguments: 
            [exec] '--classpath' 
            [exec] 'F:\Staging_FlexPLM\MED-61383-CD-120_12-0-2-0/odataInstallSupport.jar' 
            [exec] 'com.ptc.odata.windchill.install.VersionValidator' 
            [exec] 'F:\Staging_FlexPLM\MED-61383-CD-120_12-0-2-0/version.xml' 
            [exec] 'F:\ptc\Windchill_12.0\Windchill/installer/instreg/odata.ia' 
            [exec]  
            [exec] The ' characters around the executable and arguments are 
            [exec] not part of the command. 
        
       BUILD FAILED 
       F:\Staging_FlexPLM\MED-61383-CD-120_12-0-2-0\InstallRestServices.xml:172: Execute failed: java.io.IOException: Cannot run program "F:\ptc\Windchill_12.0\Windchill\bin\windchill" (in directory "F:\Staging_FlexPLM\MED-61383-CD-120_12-0-2-0"): CreateProcess error=193, %1 is not a valid Win32 application 
           at java.base/java.lang.ProcessBuilder.start(ProcessBuilder.java:1128) 
           at java.base/java.lang.ProcessBuilder.start(ProcessBuilder.java:1071) 
          at java.base/java.lang.Runtime.exec(Runtime.java:592) 
This is a printer-friendly version of Article 404064 and may be out of date. For the latest version click CS404064