Article - CS430089

Part Attributes are not updated using Export Importable Spreadsheet in Windchill PDMLink

Modified: 20-Aug-2025   


Applies To

  • Windchill PDMLink 13.0 to 13.0.2.3

Description

  • Part Attributes are not updated when using Export Importable Spreadsheet followed by Import from spreadsheet
  • Import from spreadsheet incorrectly checks all states
  • Import process points to the wrong version, not the latest one
  • It is not possible for users to Revise a Part via Import from Spreadsheet
  • Error occurs during import, pointing to an incorrect version instead of the latest version
  • Error message displayed: “Problem in export/import process. XXX user does not have Modify permission.”
  • Java stack trace indicates a lack of Modify permission as the cause of failure
Description: Description: Problem in export/import process.
Nested exception is: wt.util.WTException: 'XXX' user does not have Modify permission for [0000041150, create1, OEM, A (Manufacturing), 0000041150, create1, OEM, A (Design)]
(wt.ixb.publicforhandlers.ixbResource/8) wt.ixb.publicforhandlers.LogHelper$IxbException: Problem in export/import process.
Nested exception is: wt.util.WTException: 'XXX' user does not have Modify permission for [0000041150, create1, OEM, A (Manufacturing), 0000041150, create1, OEM, A (Design)]
    at wt.ixb.handlers.forclasses.attr.ExpImpForWTPartMasterAttr.checkModifyAccess(ExpImpForWTPartMasterAttr.java:367)
    at wt.ixb.handlers.forclasses.attr.ExpImpForWTPartMasterAttr.importAttributeBatch(ExpImpForWTPartMasterAttr.java:330)
    at wt.ixb.publicforhandlers.IxbHndHelper.importAttributeBatch(IxbHndHelper.java:1173)
This is a printer-friendly version of Article 430089 and may be out of date. For the latest version click CS430089